MagniFoam™ MFSiltec-SD Non-flammable Silicone Foam Material

DESCRIPTION

MFSiltec-SD is an open celled, compressible silicone foam material designed for a wide range of applications in multiple industries. It insulates, seals, absorbs, and protects, and is available in rolls, sheets, tape strips, or fabricated to customer design.

BENEFITS APPLICATIONS SUCH AS...
  • Low Flame, UL-94 V0
  • Very low compression set
  • Low closure force
  • Handles temperature extremes
  • UV & weather resistant
  • Automotive seals and gaskets
  • Telecommunications enclosure gaskets
  • Electronics seals and gaskets
  • Aerospace vibration damping
  • Defense flame / heat barriers
  • Carpet underlay

TYPICAL PHYSICAL PROPERTIES

Property

Test Method

Typical Value

Standard Colors

 

White, Gray, Black

Standard Thickness Range

 

1/16” to 1”

ASTM D-1056 Classification

 

1D1

Density

ASTM D-1056

12-14 lb/ft3 (192 Kg/m3)

Tensile Strength

ASTM D-412

32 psi (220 kPa)

Elongation

ASTM D-412

>100%

Compression Deflection

ASTM D-1056

2.0 psi (14 kPa) @25%

Compression Set

ASTM D-1056

 

 

       50%, 22 hrs @ 100ºC

<5%

Water Absorption

ASTM D471

<5%

Flame Resistance*

UL-94

VO and HF-1

Flame Spread

ASTM E162 / D3675

<25

Smoke Density

ASTM E662 @1.5 minutes

<20

 

ASTM E662 @4.0 minutes

<50

Temperature Range

Static

-67ºF to +392ºF (-55ºC to +200ºC)

Vertical Flammability

FAR 25.853 para (a-1)

Pass

*Rating dependant on thickness.

Data noted above is based on laboratory tests and should be used as a reference only.  Further information and additional specifications are available upon request.  Tests, claims, representations, and descriptions regarding flammability are based on standard laboratory tests, and they may not be reliable for determining, evaluating, predicting, or describing the flammability or burning characteristics under actual fire conditions, whenever used alone or in combination with other products.  Accordingly, each potential user should make an individual determination whether the flammability or burning characteristics of the product are suitable for the purpose intended by the user.

Click to Download MFSiltec-SD PDF

Acrobat Reader Required -